Technical Specifications
Specification Value Code POLEPOX-EPX 311 Number of Components 2 Density (Mixing) 1.45±0.05 g/cm³ 20°C TS EN ISO 2811-1 Solid Content (%) 100 by Weight Shore D 80 Application Thinner Not Thinned Weight Ratio A/B : 84/16 Shelf Life 40 Minutes / 23°C, 200 g. DIN 16945 Application Type Trowel Consumption 1.5 kg for a thickness of 1 mm.
Mechanical Strengths
Specification Value Compressive Strength (N/mm²)(DIN EN196) ~50 Structural Strength (N/mm²) (EN 1542, EN ISO 4624, EN 12118) >1.5 (Concrete Surface) Bending Strength (N/mm²)(DIN EN196) ~25 Temperature Resistance (DIN 53 109 (Taber 70mg(CS 10/1000/1000) 8days/+23°C) Temperature Test
Drying Time
Temperature Pedestrian Traction Mechanical Strength Chemical Strength +10 °C 72 hours 5 days 10 days +20 °C 24 hours 4 days 7 days +30 °C 18 hours 2 days 5 days
Decking Waiting Time
Temperature Minimum Maximum +10 °C 30 hours 3 days +20 °C 24 hours 2 days +30 °C 16 hours 1 day
Surface Preparation
To achieve the highest level of performance, sandblasting should be carried out at the Tu 2 ½ level. The sandblasted surface should be primed with an epoxy primer rich in zinc powder or an epoxy primer rich in zinc phosphate, as well as the necessary dry film, taking into account the product information.
For concrete surfaces, the concrete surface should be clean, firm and have sufficient compressive strength (>25N/mm²), tensile strength >1.5N/mm². The concrete floor to be insulated must be solid there should be no play on the surface. The coating layer on the surface must be removed without fail. The concrete to be insulated must be at least C25, preferably C30 – C35 standard.
Packaging
A COMP: 21 Kg
B COMP: 4 Kg
-
-
For high-strength surfaces that combine aesthetics,